  page 1 of 5 ? low profle case, module depth only 55 mm ? suitable for mounting in domestic installation panels ? very high effciency and low standby power - compliance to eco-standard ? high power density ? low output ripples and spikes ? suitable for household appliance and industrial applications ? for distributed power ? ul 1310 class ii, nec class 2 compliance ? ul 508 listed ? universal input range 85 to 264 vac ? operating temperature range: C25c to +70c ? adjustable output voltage ? short circuit and overload protection ? dcCok indicator led this new din-rail mounting power supplies are designed for industrial and resi - dential applications. they are lower cost than the existing tbl range, with similar electrical specifcations. additionally, they fully comply to the new standby power and effciency requirements (eco standard). they are intended for connect - ing as class ii devices, so the safety earth connection is not required. they are mountable in fat racks due to their small dimensions in depth. their dimensions comply to the din 43880 standard. order code output power (max.) output voltage* (nom.)(adjustable) output current (max.) effciency (typ.) tblc 06-105 6 w 5.0 vdc 1.2 a 74 % tblc 06-112 6 w 12 vdc 0.5 a 81 % tblc 06-124 6 w 24 vdc 0.25 a 79 % tblc 15-105 12 w 5.0 vdc 2.4 a 81 % tblc 15-112 15 w 12 vdc 1.25 a 85 % tblc 15-124 15 w 24 vdc 0.63 a 85 % tblc 25-105 20 w 5.0 vdc 4.0 a 82 % tblc 25-112 24 w 12 vdc 2.0 a 86 % tblc 25-124 25 w 24 vdc 1.05 a 87 % tblc 50-112 48 w 12 vdc 4.0 a 88 % tblc 50-124 50 w 24 vdc 2.1 a 89 % tblc 75-112 72 w 12 vdc 6.0 a 89 % tblc 75-124 75 w 24 vdc 3.1 a 89 % tblc 90-112 90 w 12 vdc 7.5 a 90 % tblc 90-124 90 w 24 vdc 3.75 a 90 % models ul 50 8 cb scheme ul60 95 0- 1 http://www.tracopower.com industrial power supplies tblc series, 6 C 90 w
page 2 of 5 all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. input specifications input voltage C nominal ranges 100 C 240 vac; 50/60 hz C effective ranges 85 C 264 vac; 47-63 hz (below 100 vac a derating of 2 %/v is required) input voltage frequency 47 C 63 hz no load power consumption 6C50 w models: < 0.3 w 75C90 w models: < 0.5 w harmonic limits en 61000-3-2, class a leakage current 0.25 ma max. inrush current 6C50 w models: 15/30 a (115 / 2 3 0 va c ) 75C90 w models: 25/50 a (115 / 2 3 0 va c ) output specifications output voltage / current 5 vdc models: 5.0 C 5.5 vdc* 12 vdc models: 12.0 C 16.0 vdc* 24 vdc models: 24.0 C 28.0 vdc* regulation C input variation 0.3 % max. C load variation (10C90 %) 0.3 % max. hold-up time 60 ms min. (at 230 vac) 15 ms typ. (at 115 vac) start-up C start up behavior tblc 75-112 and 90-112: 0-75 % constant current load other models: 0-100 % constant current load C start up time 1 s max. ripple and noise (20 mhz bandwidth) 50 mvp-p max. current limit (continuous) 105 C 130 % of iout nom., constant current short circuit current tblc 75-112 and 90-112: 70 C 90 % of iout nom. (typ.), foldback other models: 120 C 200 % of i out nom output overvoltage protection 150 % of vout nom. (typ.) dc ok signal C trigger threshold on > 95 % of the set voltage general specifications operating temperature C25c to +70c derating above +55oc: 2.5 %/k storage temperature C40c to +85c temperature coefficient 0.02 %/k cooling convection cooling, no internal fan pollution degree 2 humidity (non condensing) 5C95 % rel. h max. altitude during operation 4800 m max. isolation C i/o isolation 3000 vac (4242 vdc) class of protection safety class ii degree of protection ip 20 (iec/en 60529) reliability, calculated mtbf (at 25c acc. to iec 61709) > 1.9 mio. h * output voltage can be adjusted as indicated. however, output power has to be maintained at nominal value. this means the output nominal current has to be reduced in accordance with the increase of output voltage. http://www.tracopower.com tblc series, 6 C 90 w
page 3 of 5 general specifications (continued) safety standards C information technology equipment iec/en 60950-1, ul 60950-1 C household applications iec/en 60335-1 C safety of machinery en 60204 C safety for power electronic converter systems iec/en 62477 C industrial control equipment ul 508 C class ii power units ul 1310 C nec class 2 ul 1310 (not tblc 90-xxx and tblc 75-112) C electronic equipment for power installation en 50178 C safety of transformers en 61558-2-8, en 61558-2-16 C certification documents www.tracopower.com/overview/tblc electromagnetic compatibility (emc), emissions en 61000-6-3, en 61204-3 C conducted ri suppression on input en 55032 class b C conducted disturbance on output tblc 50/75/90: en 55014 class b, cispr 16-1-1 C radiated ri suppression en 55032 class b C harmonic current emissions iec 61000-3-2 class a electromagnetic compatibility (emc), immunity en 61000-6-2, en 61204-3 C electrostatic discharge (esd) iec/en 61000-4-2 4 kv/8 kv criteria b C radiated rf field immunity iec/en 61000-4-3 10 v/m criteria a C electrical fast transient / burst immunity iec/en 61000-4-4 2 kv criteria b C surge immunity iec/en 61000-4-5 1 kv/2 kv criteria b C immunity to conducted rf disturbances iec/en 61000-4-6 10 v criteria a C power frequency field immunity iec/en 61000-4-8 30 a/m criteria a C mains voltage dips and interruptions iec/en 61000-4-11 0% / 20 ms 40% / 200 ms 70% / 500 ms environment C vibration acc. iec 60068-2-6 3 axis, 2 g sine sweep, 10 C 150 hz, 90 min C shock acc. iec 60068-2-27 3 axis, 30 g half sine, 11 ms enclosure material v2 rated plastic mounting C din-rail mounting for din-rails as per en 50022 C 35x15/7.5 (snap-on with self-locking spring) (included) environmental compliance C reach www.tracopower.com/products/reach-declaration.pdf C rohs rohs directive 2011/65/eu connection screw terminal with combi-type screw heads for wire size 0.5 C 2.5 mm 2 http://www.tracopower.com tblc series, 6 C 90 w
page 4 of 5 block diagram current limit characteristic the load characteristic is designed to accomplish reliable start-up of heavy loads. note: all 6 watt models (tblc 06-xxx) implement a pulsing power characteristic when in overload or short circuit conditions. 120% o t h e r m o d e l s i short = 120 - 200% of i nominal 7 0 % t b l c 7 5 -112/90-112 i short = 7 0 - 90 % of i nominal 2 0 0 % 90% iout vout nominal (100%) function specification http://www.tracopower.com all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. tblc series, 6 C 90 w
www .tracopowe r. com ? copyright 2017 traco electronic ag sp ec i?cati ons can be changed wi thout noti ce! page 5 of 5 outline dimensions 43.5 mm 54.5 mm 59.5 mm 45 mm 89.5 mm a din 43880 size 1 weigth model width a [g] tblc 06 18 mm 60 tblc 15 27 mm 80 tblc 25 36 mm 110 tblc 50 54 mm 180 tblc 75 72 mm 220 tblc 90 90 mm 280 description wire size torque ac input all models: l, n only 2 pin terminal awg 20 C 14 05 C 25 mm ma 05 nm dc output 6 C 50 w models: single terminal awg 20 C 14 05 C 25 mm ma 05 nm dc output 75 C 90 w models: double terminal awg 20 C 14 05 C 25 mm ma 05 nm wiring tolerances: 05 mm wall mounting bracket instead of on a din-rail, the modules can also be mounted on a chassis or wall with help of a mounting bracket which is supplied as standard with each power supply rev. december 6, 2017 tblc series, 6 C 90 w


▲Up To Search▲   

 
Price & Availability of TBLC15-112

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X